Features:
Ø 10.4" Portable, compact, AC power and internal rechargeable battery; Ø Automatically and rapid charge, 80-90% power will be recharged for 3 hours; Ø New design of NIBP module, support rapid and continuous measurement, higher precision and consistency; Ø Multi-bandwidth design of ECG module, adapt to various conditions; Ø Resistant high-frequency electrosurgical generator design, reliable and special module is used in operation room; Ø The software is easily to update, no need to open the monitor cabinet; Ø Optional inner printer with 3 channels wave or external printer; Ø Adjust volume more accurately by digital system; Ø Menu design adopts Huffman decode, operating more effectively; Ø Support Ethernet, wireless LAN and could connect with Central monitoring system.
Technical Specifications
Safety Meet the requirements of IEC60601 serials standards, CE marking according to MDD93/42/EEC
Dimension and Weight Dimension: 335mm (W) × 245mm (H) × 175mm (D) Weight: 3.7Kgs without battery 5.0Kgs with 1 battery
Operation Environment Power: AC100 - 240V (±10%), 50/60 Hz (±1 Hz) Temperature: +5��nbsp;to +40�� Humidity: ≤80%, non-condensing
Patient Range Small size animal or middle size animal
Performance Specifications Display: 10.4″ color active matrix TFT Resolution: 640×480 Trace: 9 waveforms maximum (801 function boards) 6 waveforms maximum (608 function boards) Indicator: Power indicator light QRS beep and alarm sound Battery: Built-in rechargeable battery Battery life: 2 hours minimum Trend time: 1-72 hours Alarm: 3-level audible and visual alarm Networking: LAN / Wireless LAN to central station Recorder (optional): Built-in, thermal array, 3channels Record width: 48mm,(record paper 50mm) Record speed: 25mm/s Other: medicine, oxcart, trends in one screen
ECG Lead Type: 5-lead or 3-lead selectable (608 function board) 5-lead only (801 function board) Input: 5-lead: RA; LA; RL; LL; V or R; L; N; F; C 3-lead: RA; LA; LL or R; L; F Lead Selection: 5-lead: I; II; III; aVR; aVL; aVF; Vx I, II, III, aVR, aVL, aVF, V (n) 3-lead: I; II; III ECG Waveform: 7 channels (801 function boards) 1 channels (608 function boards) Gain Selection: 0.25, 0.5, 1.0, 2.0, 2.5 (mm/mV), auto Sweep Speed: 12.5mm/s, 25mm/s, 50mm/s
Heart Rate Range: 30-350bpm Accuracy: ç«ï¿½00 bpm ±1 bpm or ≥100bpm ±2% Resolution: 1 bmp Bandwidth: Diagnostic mode: 0.05-100Hz Monitor mode: 0.5-75Hz Operation mode: 1-25Hz Calibration signal: 1mv ± 5% CMRR: >80dB S-T detection: YES Measurement range: -12mV ~ 1.2mV Arrhythmia analysis: YES Alarm: YES, audible and visual alarm
Respiration Method: RA-LL impedance Measurement Range: 0-100 rpm Resolution: 1 rpm Accuracy: 15rpm~60rpm; ≤2rpm 60rpm~100rpm; ≤5rpm
NIBP Method: Oscillometric Operation Modes: Manual/Automatic/STAT Measurement Unit: mmHg/kpa selectable Measurement Types: Systolic, Diastolic, Mean Measurement Range: Medium animal; Small animal Systolic: 30mmHg -255mmHg 25mmHg -220mmHg Diastolic: 15mmHg -220mmHg 10mmHg -150mmHg Mean Arterial: 20mmHg-235mmHg 15mmHg-160mmHg Over-pressure protection: YES Resolution: 1 mmHg
Temperature Scale: °C and F selectable Measurement Range: 0-50°C Resolution: 0.1°C or 0.1F Accuracy: ±0.1°C Channel: 1channel/ 2channel(optional) Alarm Range: 0-50°C
SPO2 Measurement Range: 0-100% Resolution: 1% Accuracy: 81~100%≤ ±2%;70~80%≤±3% 0-69% Unspecified
Pulse Rate Range: 30-350 bpm Accuracy: ç«ï¿½00 bpm ±2 bpm or ≥100bpm ±2% Resolution: 1 bpm
IBP (optional) Measurement Range: Static pressure: -50~350 mmHg Systolic: 30~240 mmHg Diastolic: 10~160 mmHg Accuracy: Static pressure: ≤100mmHg:±2mmHg;ç«ï¿½00mmHg:±2% Systolic: ≤100mmHg:±2mmHg;ç«ï¿½00mmHg:±2% Diastolic: ≤100mmHg:±2mmHg;ç«ï¿½00mmHg:±2% Channel: 2 channels Measurement Unit: mmHg/kpa selectable Resolution: 1mmHg EtCO2 (optional) Sampling Method: Built-in sidestream sensor Measurement Mode: Sidestream Measurement range: 0-99 mmHg Resolution: 1 mmHg Accuracy: CO2 concentration: ±3mmHg 0-40mmHg ±8% of reading 41-76 mmHg ±10% of reading 77-99mmHg
Stand configurations: ECG/ RESP, NIBP, Spo2, TEMP, Built-in Battery
Optional configurations: Dual-IBP, EtCO2, Thermal Recorder
|
|
|
|
| |
|
|
|