Source Medical Equipment Corp.Ltd

Patient Monitor S108

Contact Now* Send an Inquiry to this supplier.
or
Start Order * Name your price
You may also be intersted in
monitoricumonitoring

Contact us

Source Medical Equipment Corp.Ltd
[China]

Address
Room 1302,Building 1,Commercial Building,Gong Village,Sanlian Road,Longhua Town,Shenzhen,Guangdong  Shenzhen Guangdong
Phone
86-755-28130243
Contact name
Sylvia Chang

Quick Information

  • Place of Origin: China
  • Model Number : S108

Description

Detailed Product Description
 

Standard parameter: ECG, RESP, NIBP, SpO2, TEMP, PR.

12.1" large-screen color TFT display

Built-in high-capacity battery, up to 4 hours working time

7-lead ECG waveforms display ,big fonts observational interface

Reviewable ECG waveforms, Maximum 240 hours reviewing graphic trends

Digital SpO2 technique, precise measurement for weak perfusion and finger shaking

Arrhythmia and S-T segment analysis and pacemaker detection

Protection against interference from defibrillation and electrosurgical Unit

Applicable to ICU, CCU, operation, adult, pediatrics and neonatal patient

 

ECG

l          Full lead:     I, II, III, AVL, AVR, AVF and V
l          Gain       5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV
l          Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
l          Band width          0.05Hz-100Hz(3dB)
l          Heart rate:
Scope:          15 times/minute to 300 times/minutes
Accuracy:     ±1 time/minute
l          Variation of heart beat        LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period.
l          Arrhythmia :Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.   
Accuracy:     Error rate < 20%        
Undetected rate < 20%
Analysis function should be started when using the above two kinds of function.
l          ST section
Precision :     ??±0.05mV

SpO2

l          Detection scope: 0%-100%
                 ±2%    70%-89%

NIBP

l        Theory         Electric oscillator
l        Cuff gassing time   less than 15 seconds
l        First-time gassing pressure: dynamic state 24kPa ??80 mmHg??nbsp;
Manual selection: 9.3kPa ??0 mmHg???13.3kPa ??00 mmHg???16.0kPa
??20 mmHg??/div>
18.6kPa ??40 mmHg???20.0kPa ??50 mmHg???21.3kPa ??60 mmHg???
l        Automatic detection period: 1 minute to 240 minutes
Stop size?? min?? min -10min?? 5min(10 min -30min), 10min(30 min -90min) and 30min??0 min -240min??/div>
l        Detection scope:
Systolic blood pressure:     4kPa -34kPa(30mmHg -255mmHg)
Diastolic pressure              2kPa -29.3kPa(15mmHg -220mmHg)
Mean pressure            2.7kPa??1.3kPa ??0mmHg??35mmHg??/div>
l        Detection accuracy
Static pressure: ±3mmHg
Pulse rate:            ±2%

Resp

l        Chest impedance method or concentration of carbon dioxide at end of respiration
l        Scope of chest impedance method   0 time/minute – 100 minutes/minute
l        Precision of chest impedance method       1 time/minute
l        Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg??0.4%vol-9.9%vol
l        Detection scope of respiration rate: 2 times/minute ->60 times/minute  ??ncluding baby??/div>

Temp

l        Single/double path
l        Type:     Vascular/surface temperature
l        Scope:          20???50??/div>
l        Accuracy             ±0.2??/div>

Invasive blood pressure (selected mating)

l        Single/double path
l        Type: direct and continuous detection
   Scope:            -6.67kPa(-50mmHg)—46.67kPa(350mmHg)
l        Precision??nbsp;       below 13.33kPa(100mmHg) ±0.27kPa(2mmHg)  13.33kPa(100mmHg) above ±2%
l        Frequency response??nbsp;   DC-12Hz
l        Input resistance: not less than 500kΩ
l        Sensitivity of sensor: 5μV/V/mmHg
l        Motivation voltage??nbsp;   5V (DC)
l        Accuracy of sensor: ±2??/div>
l        Isolation voltage: 4 kV


Product Image

  • Patient Monitor S108 image

Send an Inquiry to this supplier

Send an Inquiry to this supplier
* From
  To Sylvia Chang
Source Medical Equipment Corp.Ltd
* Buying Product
- Please enter your specific buying item.
e.g. 42 inch LCD TV, leather executive chair
Category : Heart Rate Monitor
* Message

Use English only Max. 2000 characters. (Min. 20)

Send
EC21.com does not guarantee the validity of product information or the credentials of sellers.

Browse: Manufacturer Directory Premium Suppliers Site Map

About EC21 Contact Us Terms & Conditions Report Item Online Trading Risks Product Listing Policy

Copyright (c)1997-2026 EC21 Inc. All Rights Reserved. EC21 in KoreanChinese

Business Registry Number: 120-86-03931 | Mall order sales Registration Number: 강남-5838